Product information
S/K-150 (For Cavity widths from 150mm-165mm)
For standard load
Outer leaf 100mm
Inner Leaf 95mm
Blockwork built tight against inner face of the lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Lintels may be propped to facilitate speed of construction.
![]() | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|
| Length (mm) | Height (mm) | Thickness (mm) | Total UDL kN 3:1 | Total UDL kN 19:1 |
600 - 1500 | 100 | 2.0 | 16 | 13 |
1650 - 1800 | 118 | 2.0 | 22 | 18 |
1950 - 2100 | 130 | 2.0 | 21 | 17 |
2250 - 2700 | 148 | 2.5 | 25 | 20 |
2850 - 3000 | 173 | 2.9 | 27 | 22 |
3150 - 4000 | 173 | 3.2 | 26 | 19 |
4200 - 4800 | 199 | 3.2 | 25 | 20 |
Manufactured in lengths of 150mm increments.
Video
No video available.